Zen RTU/U 16 Channel Remote Terminal Unit

Zen RTU/U 16 Channel Remote Terminal Unit

Isolated Universal Input. Enables sophisticated monitoring and control of up to 16 input signals from a variety of sources.

Additional information

Weight 1.911 kg
Dimensions 15.3 × 27.3 × 6.7 cm
Power Supply & Port 1 Configuration (Please Select)

Med Voltage, RS232/485, Med Voltage, Ethernet Modbus, RS232/485, High Voltage, RS232/485, High Voltage, Ethernet Modbus, RS232/485

Share This Product

What it does

Enables sophisticated monitoring and control of up to 16 input signals from a variety of sources

Get 16 signals into your PLC or SCADA system

If you need to collate multiple signal input types and route them to your PLC or SCADA system, choose the Zen RTU. This exceptionally flexible and powerful monitoring and control station is the last word in RTU technology.

Enjoy the flexibility of universal inputs

If you need to collate multiple signal input types and route them to your PLC or SCADA system, choose the Zen RTU. This exceptionally flexible and powerful monitoring and control station is the last word in RTU technology.

Cleans up noise

Each of the Zen RTU channels is isolated so there’s zero cross-talk.

Set up in just minutes

No calibration and simple software set up with WorkBench.

Try Before You Buy!

Use the product simulator inside our free WorkBench software to demo how this instrument works.

Bridge Key Required!

In addition to this software a Bridge Key is required for the configuration of this product.

You must order one unless you already have one from a previous product purchase.

Files for connecting to Rockwell Automation hardware

057F000C00C90100 [EDS file], 05-Jul-2016 | (74 KB)
Zen Mapping EDSAOP [L5X file], 05-Jul-2016 | (91 KB)
Zen Mapping Generic [L5X File], 05-Jul-2016 | (91 KB)

5 Year WarrantyRCM E2180CE
5 Year WarrantyRCM E2180CE

Specifications

Input


Number of input channels: 16


Input configuration: Isolated universal inputs: Current, Voltage, RTD, Thermocouple, Potentiometer, Digital Pulse, Current Sensor or Attenuator input

See below for input specifications for each input type


Input isolation: 2,500V AC for 1 minute between all input channels


Isolation test voltage: 1000V DC for 1min between analog input channels, and between analog inputs and digital outputs


Resolution: 16 bits


Accurate to: <±0.1% fso (unless otherwise stated for specific input


Power


Power supply: HV= 85–265V AC / 95–370V DC, OR MV= 24–48V AC / 17–72V DC


Supply frequency: 50/60Hz, 10VA


Mains isolation: 250V AC


Isolation test voltage: Mains isolation test voltage 3000V AC 50Hz for 1min to all inputs and outputs


General Specifications


Noise immunity: (CMRR) 160dB tested at 300V RMS 50Hz


RF immunity: <±1% effect fso


Permanent memory: (E²ROM) 100,000 writes per input parameter


Linearity & repeatability: <±0.1%


Channel Separation: 125db minimum


Thermocouple Input


Thermocouple types: B= 32 to 3272°F (0 to 1800°C) E= -328 to 1292°F (-200 to 700°C) J= -328 to 1832°F (-200 to 1000°C) K= -328 to 2300°F (-200 to 1260°C) N= -328 to 2372°F (-200 to 1300°C) R= 32 to 3092°F (0 to 1700°C) S= 32 to 3092°F (0 to 1700°C) T= -328 to 752°F (-200 to 400°C)


Input impedance: >500KΩ min


T/C lead resistance: 100Ω max


Cold junction compensation: 14 to 140°F (-10 to 60°C)


CJC error: <0.02°c typical for all


Accuracy: 0.1% of FSO±1°C typical


Sensor open: Upscale


RTD Input


RTD input type: Pt100 3 wire RTD DIN 43760: 1980 Pt1000 3 wire RTD standard


Range: -328 to 572°F (-200 to 300°C), 0.02°F (0.01°C) resolution,-328 to 1472°F (-200 to 800°C), 0.1°F (0.1°C) resolution


Lead wire resistance: 10Ω/lead max recommended


Sensor current: 0.6mA continuous


Sensor fail: Upscale


Accuracy: -328–572°F (-200–300°C) = ±0.1°C -328–1472°F (-200–800°C) = ±0.3°C


Ambient drift: 0.003°C/C typical


Current Input


Range: 0–20mA, 4–20mA


Input impedance: 45Ω


Max over-range: Protected by PTC to 24V DC


Linearity & repeatability: 0.1% FSO max


Accuracy: 0.1% FSO max


Channel separation: 0.001% max


Ambient drift: 0.003%/°C FSO typical


RF immunity: 1% effect FSO typical


Fail safe micro switch: Prevents external loops from being interrupted in the event of a power loss to the Zen


Voltage Input


Ranges: ±200mV, –200mV to 1V, 0–10V, 0–18V


Input impedance: >500KΩ on all ranges


Maximum over voltage: 24V DC


Linearity & repeatability: 0.1% FSO max


Accuracy: 0.1% FSO max


Channel separation: 0.001% max


Ambient drift: 0.003%/°C FSO typical


RF immunity: 1% effect FSO typical


Digital Pulse Input


Frequency range: 0–2500.0Hz


Fast counter range: 0–2500.0Hz


Sensors: Open collector (NPN, PNP), TTL or Clean Contact


Frequency resolution: 0.1Hz


Frequency resolution: 0.1Hz


Debounce counter range: 0–50Hz max


Counter register output: 32 bit


Accuracy: ±0.5%


AC Current Sensor Input


Sensor type: Current transformer ACCS-420, ACCS-420-L and ACCS-010


Amperage range: Header selectable ACCS-420/010= 100/150/200A, ACCS-420-L= 10/20/50A


Overload: (continuous) ACCS-420/010= 175/300/400A respectively, ACCS-420-L = 80/120/200A respectively


Output: (Representing 0–100% of full scale input range) ACCS-420(-L)= 4–20mA DC loop powered, ACCS-010= 0–10V DC


Power supply: ACCS-420(-L)= Loop powered, 15–36V DC ACCS-010= Self powered


Accuracy: 1% of full scale


Response time: 250ms (10–90%)


Isolation voltage: 2000V


Frequency: 50–60Hz


Features


Expansion interface: Add 16 relay outputs and 16 digital control inputs with a ZEN-RIO Relay/IO Expansion


HMI interface: For FM1602 Remote Display


Potentiometer Input


Potentiometer input: 3-wire


Excitation voltage: Variable


Potentiometer resistance: <2kω low pot;>2kΩ high pot


Field programmable zero: 0–90% of span


Field programmable span: 0.1–100%


Linearity & repeatability: <±0.05% fso


Response time: 100msec


Ambient drift: <50ppm


Relay Output


Number of relay outputs: 2


LED indication: of each output


Isolation: Isolated


Contact rating: 5A 30V DC


Analog Output (Retransmission)


Number of analog outputs: 2


Analog output type: Isolated 4-20mA analog outputs


Isolation test voltage: 1000V DC for 1min between analog output and digital output


Resolution: 15 bits, 16,000 steps


Compliance voltage: 10V 500Ω


Intelligent Multiplexer


Channel selection: Binary (digital inputs)


Cycle time: 4sec minimum to cycle through all 16 inputs


Resolution: 12 bits, 4000 steps typical


Comm Port(s)


Protocols: Modbus RTU, RS232, RS422 or RS485


Port 1: Select either: RS= RS422 / RS485 OR EMOD= Ethernet Modbus (10/100/Auto)


Port 2: RS232 / RS485 auto-select Selectable baud rate 2400–230000 baud. Format: 8 bit, no parity, 1 stop


Isolation test voltage: 1000V DC for 1min between comms and analog input/output, and between comms and digital input/output


Digital Inputs


Number of digital inputs: 4 x Opto isolated inputs


LED indication: of each digital input


Functions: Status, up counter, up/down counter with direction, debounced counter, frequency, gated frequency


Counter register output: 32 bit


Frequency range: 0–10,000Hz


Input voltage: 5–30V DC


Threshold: 4.6V typical


Debounce counter range: 0–100Hz


Load: At 5V DC= 1.1mA; At 24V DC= 7mA


Isolation test voltage: 1000V DC for 1min between digital input and analog input/output, and between digital input and digital output


Data Logging


Real-time clock:


Data logging: to Micro SD card (supplied). Logging to onboard memory when Micro SD card removed


Micro SD card capacity: 1GB (7,858,683 samples for all channels) Not compatible with higher-capacity Micro SD cards


Onboard memory capacity: 32MB (31,774 samples for all channels) Used when Micro SD card is removed


Datalog retrieval: Fast, simple datalog retrieval and visualization using Define WorkBench


Programming


USB programmable: Via USB prog port using Bridge Key USB programmer (sold separately)


Define WorkBench: Simple configuration and data log retrieval using Define WorkBench


Construction


Casing: DIN 35 rail mounting; Material: ABS inflammability V0 (UL94)


Dimensions (H x W x D): 2.32 x 10.04 x 5.67″ (59 x 255 x 144mm), with plugs in


Weight: ZEN-LOG-RS = 27.2oz (770g) ZEN-LOG-EMOD = 27.7oz (784g)


Environmental Conditions


Operating temperature: 14 to 140°F (–10 to 60°C)


Storage temperature: –4 to 176°F (–20 to 80°C)


Operating humidity: 5–85% RH max, non-condensing


Environmental Conditions


EN 61326-1: Complies with EN-61326-1:2006


EMC: Emissions EN 558022-A; Immunity EN 50082-1; Safety EN 60950

Files

Documents


Zen Register Supplement 18V01, 04-Oct-2018 | (3660 KB)
Zen RTU Logix Integration User Manual 15V03, 16-Jun-2015 | (1371 KB)
Zen RTU Manual 17V01, 20-Sep-2017 | (3276 KB)
Zen RTU Datasheet 17V01, 19-Sep-2017 | (738 KB)

Files for connecting to Rockwell Automation hardware


057F000C00C90100 [EDS file], 05-Jul-2016 | (74 KB)
Zen Mapping EDSAOP [L5X file], 05-Jul-2016 | (91 KB)
Zen Mapping Generic [L5X File], 05-Jul-2016 | (91 KB)

Software


Define WorkBenchDefine WorkBench

Simple software to program your Zen series or edge processing device

Use Define WorkBench to simulate, configure and view data for all Zen series control stations and Nimbus IoT Gateways, including:

With a user-friendly, uncluttered design, WorkBench offers a simple interface for setting up and scaling your unit, as well as retrieving and graphing your datalog.

N.B. Version 3 features Simulation Mode and is only compatible with legacy ZEN-16 firmware 2.0.0 and later.


Define WorkBench


Define CodeLabDefine CodeLab

Flexible macro programming of your Zen series device

Define CodeLab enables you to write and compile a macro using the BASIC programming language, for fully flexible programming of your Zen series device. CodeLab is compatible with all Zen devices, including:


Define CodeLab

Order Codes

ZEN-RTU

Input Type
/R Non-Isolated RTD Input (View product page)
/U Isolated Universal Input
Power Supply
-HV 85-265V AC / 95-370V DC
-MV 24-48V AC / 17-72V DC
Port 1
  No Port 1 Comm
-EMOD Ethernet Modbus
Sample order codes: ZEN-RTU/R-HV, ZEN-RTU/R-MV-EMOD

Compare

  ZEN-16 Zen Datalogger Zen RTU/U Zen RTU/R
16 Universal Isolated Inputs  
16 Non-Isolated RTD Inputs      
1GB Data Logging    
4 Digital Inputs
2 Analog Outputs    
2 Relay Outputs    
RS232/485
RS422/485    
Ethernet Modbus
Easy setup with WorkBench
Zen-RIO expansion option    
HMI Interface    
Universal AC/DC power supply  

All prices are in US Dollars. For pricing in other currencies, please contact us.